RENNtech logo NEW small v2b

Brocade sfp commands

brocade sfp commands supportshow – Like Sun’s explorer – gets many configs at once. 6610# show media et 3/3/1 6610# Port 3/3/1: Type : 10G XG-LR(SFP +) Brocade San Switch – Commands to know. italic text Identifies a variable. In actual examples, command lettercase is often all lowercase. Reset button Console management interface The console management interface is an RJ-45 serial port that allows you to configure and manage the device using a third-party terminal emulation application from a directly connected PC. In v8080 FastIron and above, Ruckus added a command that enables optical monitoring details (like the above example) for non-brocade branded optics, so you should no longer need to hunt down Brocade branded optics for detailed SFP+ reporting. Key benefits of Access Gateway mode include: • Improved scalability for large or rapidly growing How to view optical levels on a Brocade Switch? Posted on Apr 15, 2012 Written by Scape. Brocade 16Gb FC Switch Module installed in the frame. To check the fillword setting, use the portcfgshow command on the switch command console. Lid. Out-of-band management interface Is there anything special that I need to do so that the SFP ports will become enabled? (Yes I went to the interface and typed the enable command). I confirmed that both switches are able to see the SFP's and have thus far been able to see all of the modules I've tried. 0 netmask [root@mdw ~]# ssh admin@i-sw-1 admin@i-sw-1's password: ----- i-sw-1:admin> cmsh 2. 10 aaaconfig Configure RADIUS for AAA services ad Specifies all administration domain… Some switches like Cisco, Hpe, Brocade will offer CLI (Command-Line Interface) reference for users to view SFP modules DDM/DOM information, which includes transceiver temperature, the supply voltage in the transceiver, laser bias current, RX power TX power (mW or µW or dBm). Switch#show optic 9/1. . serving the new Brocades 6505, 6510 or 6520). Basic Troubleshooting of Brocade SAN Switch. As you can see this is exactly – our Port Index. Purchased the required 10G Brocade licenses and applied them to both switches. Use the following command to get a summary of all port tests on the switch: Sw2:admin> portdporttest --show all Port State SFP Capabilities Test Result ===== 23 ONLINE E,O PASSED. 2 Fabric OS: v7. Out-of-band management port 6. • Chapter 3, “Brocade VDX 6710-54 Configuration” lays out the tasks and commands necessary The Brocade TurboIron 24X is a switch that was EOL’d in early 2017. Listed below are few of the Brocade Fabric OS RADIUS Configuration Examples. 233 Tian He Road North Unit 1308 – 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade. And use this command to get a lot of nice detailed information about a specific port: Sw2:admin> portdporttest --show 23 Usually, the SFP optical transceiver data table provides key information such as link range, fiber type, output power, and received power. portstatsshow <port> – Provides details of port errors. EMC Support, Anti Electro-Static Discharge and Radiation Resistant. One or more ports or components on the Brocade switch may go offline permanently. 393: slotshow: Displays . The steps will be done in command line (CLI), because I hate java. S Rathore / April 4, 2015. The Brocade FastIron SX series of Layer2/3 switches provide a superior scalable foundation for improved operational efficiency and faster response to business opportunities today and into the future, extending control from the network edge to the backbone with intelligent network services, including . For complete descriptions of all Fabric OS commands, including syntax, operand description, and sample output, refer to the Fabric OS Command Reference. The item is the port-number as two-digit or three-digit string (on switches with 100 or more ports) as printed on the switch (note: the SNMP-index of port {00} is {1}!). Too many counts of er_bad_os indicate that packets were dropped from the SAN, causing latency or link failure. Call Brocade support (1-800-752-8061) and use the case number the switch was replaced under. lines of a command input, enter the entire command at the prompt . Page 6 of 48 • Brocade – FabricOS Command Reference – Publication #53-1002921-01, 26-July 2013 • Brocade – FabricOS Message Reference– Publication #53-1002929-01, 26-July 2013 TOE Developer – Brocade Communications Systems, Inc. Checking the port status on the SAN switch. In terms of hardware, the hardware of the Brocade TurboIron 24X and the Quanta LB6M were nearly identical which means one simply needs a license and the ability to boot the software on the new switch. 5 miles); and extended long-wave up to 100 km (62. Otherwise, this manual specifically notes those cases in which a command is case sensitive. Additionally, the switch may become unresponsive to SSH or web commands in some situations. If you have purchased Brocade product support directly from Brocade, use one of the following methods to contact the Brocade Technical Assistance Center 24x7. It's not guaranteed to work with all optics, but should with most that conform to SFF-8472. This is a list of useful Brocade switch commands that will help you for administration or management operation. The show flash command displays the Type, Vendor, Part number, Version and Serial number of the SFP, SFP+, QSPF, or QSPF+ optical device installed in the port. In these examples, the host FC HBA port is connected to port number: 0 on the FC switch. Brocade Switch Commands. Each SFP transceiver module is individually tested to be used on a series of Brocade . They both provide the 8×1/10 Gbps SFP/SFP+ ports and 48×10/100/1000 Mbps RJ45 ports in the front. 7mode Architecture Brocade Cisco Classes of service CNA commands configDefault configDownload configUpload configuration backup Congestion console messages Converged Network Adapter DMX fiber fibre Fibre Channel fundamentels G200 G400 G600 G800 G1000 HBA health check Hitachi Hitachi Dynamic Provisioning (HDP) Hitachi USP Hitachi VSP Hop MDS . YQA-48K-F5C1:sfmon> sfpshow 10/29. Universal Transceivers that work with nearly every device. If this switch required shared area addressing (basically more than 255), the first 8 bit of Node ID would be “borrowed” as Area ID as well. network edge. And use this command to get a lot of nice detailed information about a specific port: Sw2:admin> portdporttest --show 23 Universal Transceivers that work with nearly every device. xxx –id admin –pw password –s self –fid 128 –sfp sfp_rules_r9. Login Procedure for the SAN switch. 53-1002817-02 24 June 2013 ® Brocade ICX 6430-C Compact Switch Hardware Installation Guide Supporting software release 08. Show optic. debug hal show optic-info slot 1 show ports 1:25 transceiver information detail sh ports 2:25 information detail Thanks. • Chapter 2, “Brocade VDX 6710-54 Installation” provides the information needed to install the switch in your network. Brocade ICX 7450 Switch Hardware Installation Guide 3 . The Brocade Fabric OS CLI commands, sfpshow and portshow shown in Figure 4 and Figure 5 sends an RDP ELS request to collect diagnostics information of the host HBA port. Media otypes Small Form-Factor Pluggable (SFP) laser. 0. Command syntax conventions Command syntax in this manual follows these conventions: command Commands are printed in bold. 0. Config. The list of Brocade SAN Switch CLI commands() version Kernel: 2. The command won't autocomplete and, as is implied, it is unsupported but allows the use of 3rd party optics. However, Brocade ICX 6610-24P is additionally available with PoE/PoE+ support. 6610# show media et 3/3/1 6610# Port 3/3/1: Type : 10G XG-LR(SFP +) Brocade 8000 Switch Useful Commands 1. The switch offers a rich set of standard software features with the options to expand its capabilities as needed. Brocade FastIron SX Series Switches Brocade FastIron SX Series Switches: FSX-800 and SX-1600. BROCADE Commands (FC Switch) P. DRAFT: BROCADE CONFIDENTIAL Command examples This book describes how to perform configuration tasks using the Fabric OS command line interface, but does not describe the commands in de tail. I have another ICX-6450-24P that I'm using for the other end of a . 255. Brocade 6505 FC SAN Switch SFP. IP address and corresponding subnet mask and gateway address recorded during the Set the switch Ethernet IP address procedure. Also provided are details for operating and replacing the Brocade M6505 16 Gbps Fibre Channel SAN I/O Module, removing and replacing SFP+ transceivers and cables, changing between Access Gateway mode and Native Fabric mode, activating Ports on Demand (POD), DRAFT: BROCADE CONFIDENTIAL Command examples This book describes how to perform configuration tasks using the Fabric OS command line interface, but does not describe the commands in de tail. g. NetApp Interoperability Matrix Tool It is common for organizations to modify default SFP thresholds. The following procedure and information will help determine if a Brocade SFP has failed. Preface Brocade VDX 6740 Hardware Installation Guide 8 53-1002829-08 Config. Digital diagnostics monitoring is available via a 2-wire serial interface, as specified in SFF-8472. HPE BladeSystem CLI Commands. Configure “optical-monitor” under the interface. Print Serial ID SFP information: 388: shellflowcontroldisable: Disable xon-xoff flow control on console serial port: 389: shellflowcontrolenable: Enable xon-xoff flow control on console serial port: 390: sleep: Linux sleep command: 391: slotpoweroff: Removes power from a slot. VCSEL+PIN, Low Power Consumption ≤0. 0 netmask 172. 00a on device models ICX 6430-C12 Brocade Communications Systems Co. Key benefits of Access Gateway mode include: • Improved scalability for large or rapidly growing Brocade Advanced FICON Acceleration — Allows use of specialized data management techniques and automated intelligence to accelerate FICON tape read and write and IBM Global Mirror data replication operations over distance, while maintaining the integrity of command and acknowledgment sequences. Slot 3 (SFP uplink ports) 5. In addition, some switches like Cisco and Brocade SAN switches will offer CLI (Command-Line Interface) reference for users to view SFP modules details which includes SFP rate, serial number, Part Number, accept/send direction optical signal strength. 0c Made on: Tue Apr 16 18:06:01 2013 Flash: Wed Dec 11 16:18:22 2013 BootProm: 1. Short-wave up to 500 m (1640 feet); long-wave up to 25 km (15. Port Temperature Tx Power Rx Power Tx Bias Current. short reach SFP with multi-mode fiber B. It is a popular industry format. switchshow – Indicators like no light or In_sync will be displayed. It interfaces a network device motherboard (for a switch, router, media converter, or similar device) to a fiber optic or copper networking cable. py –ip xxx. Fully Compatible with 200+ Vendors. This is an interesting command. b. The output of the command will be as shown in the following screenshot. NetApp Interoperability Matrix Tool Brocade ICX 7450 Switch Hardware Installation Guide 3 . Fighting with Brocade MLXe and its invalid modules. a. This document assumes the reader does not necessarily have access to various management applications, but does have command line interface access to the switch. 00 – this is the Node ID – 00, because to this port only one Node is connected directly / No NPIV. Apr 18, 2021. licenseshow – Show license data. Fabric services Standard services include Simple Name Server, Console to the Brocade SAN Switch with default username = admin & Password = password to configure the IP Address Warning: Default password not changed for 'root'. Security Requirements Section Level Brocade Switch Run the sfpshow portnum command to check the SFP information about a port. Check for CRC and EncOut errors by running porterrshow command; If there are CRC and EncOut errors it clears the port statistics and wait for 20 minutes to monitor the incremental errors on the switch ports using portstatsclear and portshow commands; Check and compare Lr_in & Ols_Out and Lr_out and Ols_in values to detect faulty cable and SFP issue • Chapter 1, “Brocade VDX 6710-54 Introduction” provides an overview of the Brocade VDX 6710-54 switch. -argument, arg . Why Write This Post? I was reading Brocade's forums and many were talking about using fabric merge tools and that the two fabrics must have different names, and there was a lot of wrong or outdated information that no longer applies to the new Fabric OS 7. Security Requirements Section Level Brocade Communications Systems Co. xxx. com This is an interesting command. I've tried brocade to brocade and brocade to Cisco 3560 (that is in production). The license ID. 28. By P. It uses several SNMP OIDs from the fibre channel switch MIB (SW-MIB) and from the Fabric Alliance Extension MIB (FA-EXT-MIB) in order to create one service check for each SFP found in an enabled and active port on the system. 248. , Ltd. It delivers dependable 10 GbE connectivity over fiber cable, for 10GBase-SR compliant networks, with a maximum distance of up to 300 m (984 ft). For ISL ports (inter-switch-links), an {ISL} is appended to the item, e. Distance depends on fiber optic cable and port speed. Brocade E1MG-SX-OM compatible SFP transceiver supports up to 550m link lengths over multi-mode fiber (MMF) using a wavelength of 850nm via an LC connector. Fibre Channel (SAN) If I get a dollar for each time I searched for a SAN Switch command to achieve something, I would have been a one tenth of a millionaire by now Below is the cheat sheet I compiled to prevent me from becoming that one tenth of a millionaire. (Shenzhen WFOE) Citic Plaza No. If a switch needs to be replaced, we may need to "de-license" the old switch. multi_capture. Brocade 10G-SFPP-SR-I Compatible 10GBASE-SR SFP+ 850nm 300m Industrial DOM LC MMF Transceiver Module #111895. 1. Brocade Communications Systems, Inc. #1. 1 miles). Displays the media type for the specified stack. type and Info? Apart from these command? I tried these command but can't grab required info. Reads a list of login credentials from a file and does the following: Contents Preface. 7840 BR -7840 0002 80-1008000-01 7840, 42P, 24 16G LW SFPS, 0 1/10/40GBE SFP Table 2 - Switch Platforms Figure 1 - Brocade 7840 Figure 1 illustrates the Brocade 7840 cryptographic module. I just want to see a live link. Part No. Likewise, Brocade ICX 6610-48P has the additional PoE/PoE+ support. The combination of the switch port and SFP must support the speed. Please login as 'root' to change it. The 'sfpshow' command is used to troubleshoot a faulty Small Form-factor Pluggable (SFP) on a Brocade switch. Usually, the SFP optical transceiver data table provides key information such as link range, fiber type, output power, and received power. It offers market‐leading stacking density with up to 12 Description. a5 – this is the Area ID – a5 hex = 165 dec. The index number specifies the software license file for a specific stack. Brocade Gen 5 (16-Gbps) fixed-port switches • Brocade 6505 Switch • Brocade 6510 Switch We have already discussed about, Brocade SAN switch Zoning steps Via CLI and CISCO MDS Zoning steps via CLI This write-up, focuses on the basic trouble shooting commands used in Brocade SAN switch. This utility configures MAPS policy for SFP thresholds read from an Excel Workbook. The Small Form-factor Pluggable (SFP) is a compact, hot-pluggable transceiver used for both telecommunication and data communication applications. 14. The ISL must be using one of the supported speeds: 4 Gbps, 8 Gbps, or 16 Gbps. shellflowcontroldisable Disable xon-xoff flow control on console serial . Designed to enable maximum flexibility and reliability, the Brocade 6505 is configurable in 12 or 24 ports and supports 2, 4, 8, or 16 Gbps . The Brocade 300 is a 1U rack-mount 8 Gb Fibre Channel switch with up to 24 ports (8 ports licensed by default; the remaining ports can be licensed in 8-port increments) that support 2/4/8 Gbps speeds. --option, option Command options are printed in bold. F5 BIG-IP CLI Commands. These commands are useful for for Zoning, Show, Port, Time/Date, License, Banner, Password, SNMP, User Config, Firmware, and Miscellaneous. 5 Brocade-A:admin> portcfgshow 0. For more information, refer to the Brocade Analytics Monitoring Platform documentation and release notes. Brocade Fabric OS Zoning Configuration Examples. HPE (H3C) CLI Commands. py map_config. {00 . 5W (Typical) Industrial Temp -40°C to +85 °C. Here is just a reference for people to have a quick look and search. sfpshow Print Serial ID SFP information. The Brocade 6505 SAN Switch provides exceptional price/performance value, combining flexibility, simplicity, and enterprise-class functionality in an entry-level switch. Cisco IOS, NX-OS CLI Commands. I2C access failures leading to various symptoms such as: slotshow command output may flag some components with an "*", indicating no i2c access to that component. Item. If none of these optical devices are installed in a port, the "Type" field will display "EMPTY". porterrshow – provides gist of port errors, look for delta of counters. I have used: . com Title Publication number Summary of changes Date Network OS Command Reference 53-1002081-01 New document December 2010 The Brocade ICX 7450 Switch delivers the performance, flexibility, and scalability required for enterprise Gigabit Ethernet (GbE) access deployment. 170 i-sw-1 # top 8000 switch with 255. Need to know what hardware the GBIC is? How about anything else? Use the 'show media' command. The Brocade 6505 in Access Gateway mode* can connect servers to NPIV-enabled Brocade B-Series, Brocade M-Series, and other SAN fabrics. Access Switch(FOS) [root@mdw ~]# cat /etc/hosts|grep i-sw 172. Brocade portshow command. This number is embedded in the Brocade device. As part of our on-going improvements to Atlantic Metro’s backbone, we have acquired many shiny new Brocade MLXe routers. RJ45 Copper SFP for Gigabit Ethernet ports. Cisco and Brocade SAN switches provide a command-based interface reference for users to view detailed information about SFP optical transceiver, including SFP optical transceiver speed, serial number, part . The Brocade 5000 switch is a 1U Fibre Channel switch with 32 fixed Fibre Channel SFP ports that supports link speeds up to 1, 2, or 4 Gbit/sec. Installing an SFP or SFP+ transceiver . SFP, SFP+, XFP, QSFP+, SFP28, QSFP28, CFP, CFP2, CFP4, Fiber Optic Patch Cables Fast delivery Typically you can run 8G Fibre Channel SFP+ up to 25km for single mode fibre in Brocade Fabric OS (e. Tried to use multiple SFP's to rule out a module issue. Description. The XBR-000180-ST is a Brocade XBR-000180 compatible fiber transceiver module that has been designed, programmed and tested to work with Brocade brand switches and routers. HPE Integrity server CLI Commands. com Title Publication number Summary of changes Date Network OS Command Reference 53-1002081-01 New document December 2010 Brocade Access Gateway mode: F_Port and NPIV-enabled N_Port Data traffic types Fabric switches supporting unicast, multicast (255 groups) and broadcast Media types 4 Gbit/sec: requires Brocade hot-pluggable, Small Form-factor Pluggable (SFP), Lc connector; 4 Gbit/sec Short-wavelength Laser (SwL); 4 Gbit/sec Long-wavelength Laser The Brocade ICX 7450 Switch delivers the performance, flexibility, and scalability required for enterprise Gigabit Ethernet (GbE) access deployment. configshow – Show switch config. Upon successful upgrade, you will have several new features: 1GbE SFP support. Once logged into the switch with admin privileges, execute the command Switchshow. agtcfgshow – Show SNMP config. . The "F1" and "F2" ports will take an SFP+ transceivers, and in fact the unit came with two 1GBASE-LR transceivers. portshow <port> – Provides report on errors on a port. 1. Issue. 2. It is common for organizations to modify default SFP thresholds. 5 The show license command displays the following information: Output field. The 44W4408-ST is a Brocade 44W4408 compatible fiber transceiver module that has been designed, programmed and tested to work with Brocade brand switches and routers. diagnostics and LEDs supporting the Brocade M6 505 16 Gbps Fibre Channel SAN I/O Module. See full list on rcannings. Brocade often recommends that the fillword be set to 3 for 8 Gbs HBAs, consult the SAN switch vendor to confirm. switchshow – Show switch ports and connections. x (new switch firmware). Brocade Fabric OS RADIUS Configuration Examples. 2 Security Level The cryptographic module meets the overall requirements applicable to Level 2 security of FIPS 140-2. The distance can be as far as 200 km but must be supported by the FC switch model. Preface Brocade VDX 6740 Hardware Installation Guide 8 53-1002829-08 How to check connected SFP module Serial no. I then rebooted these switches to make sure the licenses were applied. Organizationscan easilyenable AccessGateway mode via Brocade Network Advisor or a CLI. I'm trying to start simple, haven't configured the vlans yet. Partner Numbers. Reads a list of login credentials from a file and does the following: 4. This check monitors the power level in dBm of brocade SFPs, as well as current and voltage. S Rathore. Once the root source of CRCs has been determined, the means to correct this situation will be provided in another document titled “How to resolve CRC errors”. Fortinet Fortigate CLI Commands. 392: slotpoweron: Restores power to a slot. 6. Fabric OS support for the Brocade Analytics Monitoring Platform (AMP) device depends on the specific version of the software running on that platform. gbicshow – Show GBIC slots and serial numbers. Zoning Commands alicreate “Name”, “domain,port#” Used to create an alias alicreate “Name”,”portname1; portname2″ To create . Confirm with them the LID of the switch being replaced (the one that the license will be removed from) and the LID of the new/replacement switch. Judging by the temp of a 10GBase-T transceiver they are receiving power, however neither of the transceivers seem to be recognized by the switch. The index number is generated by the member unit. In the following picture, it is the model of Brocade ICX 6610-48 and Brocade ICX 6610-48P. bold text Identifies command names, keywords, and command options. SFP transceivers and compatible optical cables, as required Access to an FTP/SCP server for backing up the switch configuration (optional) This is a list of useful Brocade switch commands that will help you for administration or management operation. It includes the Brocade Fabric Operating System and Use the following command to get a summary of all port tests on the switch: Sw2:admin> portdporttest --show all Port State SFP Capabilities Test Result ===== 23 ONLINE E,O PASSED. zoneshow – Show zone and switch aliases. For better understanding of the commands, let us first understand the day to day operational challenges faced in the SAN fabric. You can use the following commands to check it on the switch: Brocade Switch. 180 i-sw-2 # bottom 8000 switch with 255. Index. The following pictures show the results of SFP module details in Cisco and Brocade switches. Contents Preface. It includes the Brocade Fabric Operating System and Console to the Brocade SAN Switch with default username = admin & Password = password to configure the IP Address Warning: Default password not changed for 'root'. value In Fibre Channel products, a fixed value provided as input to a command The show license command displays the following information: Output field. In part of preparing these for service, we ran into a little ‘gotcha’ relating to BR-MLX-1GFx24-X 24 port SFP modules. Show. HPE 3PAR CLI Commands. YQA-48K-F5C1:sfmon> sfpshow 10/29 Identifier: 3 SFP Connector: 7 LC Transceiver: 150c402000000000 100,200,400_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 43 (units 100 megabaud) Length 9u: 0 (units km) The Check_MK service check brocade_sfp monitors several metrics of the SFPs in all enabled and active ports of Brocade / Broadcom fibre channel switches. brocade sfp commands